- Unit/Units
- 100
- Unit/Units
- 1 onwards INR
Yukon Choice PC Elite- Setting New Standards of Quality Conrol
- The 1st DES with thermal insulation packing and electronic monitoring device for high quality and optimal performance.
- Yukon Choice PC elite is a Biodegradable Polymer Coronary Drug Eluting Stent. The Drug is Sirolimus which is a well-studied and clinically proven immunosuppressant.
- The Stent platform is of Stainless Steel with Microporous Stent Surface. The patented technology of micro pores acts like reservoirs for delivering the drug to the targeted site. Micro pores use vander-wall forces for the controlled released of drug. Microporous surface also reduce the polymer load to 1/4th.
- The Dual drug matrix is coated on the Abluminal side which ensures better Endothelialization and less systemic exposure of the drug.
- Shellac Resin is the top coat of the stent for smooth surface which prevents dual drug matrix break ups during stent expansion.
- To ensure protection of Sirolimus from various environmental conditions, Yukon Choice PC Elite is equipped with Polystrene thermal insulation packing. The environment controlled pack is further stored in thermocol temperature control packing thus ensuring dual powerful protection.
- The thermal insulated pack is furher monitored by an electronic montoring device TagAlert manufactured by SENSITECH USA that have built in alarms to ensure the stent remains within the desired temperature for optimal Sirolimus potency.
Product Matrix/ Ordering Information
Stent Diameter (mm) | Stent length (mm) & Article number | |||||||
8 | 12 | 16 | 18 | 21 | 24 | 28 | 32 | |
2.00 | YCET2008 | YCET2012 | YCET2016 | YCET2018 | YCET2021 | YCET2024 | YCET2088 | YCET2032 |
2.25 | YCET2208 | YCET2212 | YCET2216 | YCET2218 | YCET2221 | YCET2224 | YCET2228 | YCET2232 |
2.50 | YCET2508 | YCET2512 | YCET2516 | YCET2518 | YCET2521 | YCET2524 | YCET2528 | YCET2528 |
Stent Diameter (mm) | Stent length (mm) & Article number | |||||||||
8 | 12 | 16 | 18 | 21 | 24 | 28 | 32 | 36 | 40 | |
2.75 | YCET2708 | YCET2712 | YCET2716 | YCET2718 | YCET2721 | YCET2724 | YCET2728 | YCET2732 | YCET2736 | YCET2740 |
3.00 | YCET3008 | YCET3012 | YCET3016 | YCET3018 | YCET3021 | YCET3024 | YCET3028 | YCET3032 | YCET3036 | YCET3040 |
3.50 | YCET3508 | YCET3512 | YCET3516 | YCET3518 | YCET3521 | YCET3524 | YCET3528 | YCET3532 | YCET3536 | YCET3540 |
4.00 | YCET4008 | YCET4012 | YCET4016 | YCET4018 | YCET4020 | YCET4024 | YCET4028 | YCET4032 | YCET4036 | YCET4040 |
Compliance Chart
Balloon (mm) | Inflation pressure (bar/105 Pa | ||||||||||||||
| NP |
|
|
|
|
|
| RBP | |||||||
6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | |
2.00 | 1.90 | 1.94 | 1.97 | 2.00 | 2.03 | 2.07 | 2.10 | 2.13 | 2.17 | 2.20 | 2.23 | 2.27 | 2.32 | 2.38 | 2.41 |
2.25 | 2.15 | 2.18 | 2.47 | 2.25 | 2.28 | 2.32 | 2.35 | 2.38 | 2.42 | 2.45 | 2.49 | 2.52 | 2.55 | 2.59 | 2.62 |
2.50 | 2.40 | 2.43 | 2.21 | 2.50 | 2.54 | 2.57 | 2.64 | 2.57 | 2.67 | 2.71 | 2.74 | 2.77 | 2.81 | 2.84 | 2.88 |
2.75 | 2.65 | 2.68 | 2.72 | 2.75 | 2.78 | 2.82 | 2.88 | 2.81 | 2.92 | 2.95 | 2.98 | 3.01 | 3.28 | 3.31 | 3.34 |
3.00 | 2.89 | 2.93 | 2.97 | 3.00 | 3.04 | 3.08 | 3.15 | 3.07 | 3.19 | 3.23 | 3.26 | 3.22 | 3.34 | 3.37 | 3.41 |
3.50 | 3.37 | 3.42 | 3.46 | 3.50 | 3.54 | 3.58 | 3.67 | 3.59 | 3.71 | 3.75 | 3.79 | 3.84 | 3.88 | 3.92 | 3.96 |
4.00 | 3.85 | 3.90 | 3.96 | 4.00 | 4.05 | 4.10 | 4.21 | 4.11 | 4.26 | 4.31 | 4.36 | 4.41 | 4.46 | 4.51 | 4.56 |
Technical Data
Crossing Profile ( 2.5 mm) | 0.035/0.89 mm |
Strut Thickness ( 2.5 mm) | 0.0034/87m |
Metallic Surface Area | 16-18% |
No Foreshortening |
|
Balloon Marker Material | Platinum/ Iridium |
Entry Profile | 0.016/0.41 mm |
Proximal Shaft Diameter | 1.9 F |
Distal Shaft Diameter | 2.4 F |
Recommended Guide Wire | 0.014 |
Guiding Catheter | Min. 5 F |
- 100000 Per Month
- 1-7 Days
Ground Floor, Metro Tower, LSC, Mor Land, New Rajinder Nagar, New Delhi, Delhi, 110060, India
Phone :28742874