0

YUKON CHOICE PC

YUKON CHOICE PC
YUKON CHOICE PC
Price And Quantity
  • Unit/Units
  • 100
  • Unit/Units
  • 1 onwards INR
    Product Description

    Yukon Choice PC – World’s Longest Studied Coronary Drug Eluting Stent

     

    • Yukon Choice PC is a Biodegradable Polymer Coronary Drug Eluting Stent. The Drug is Sirolimus which is a well-studied and clinically proven immunosuppressant.
    • The Stent platform is of Stainless Steel with Microporous Stent Surface. The patented technology of micro pores acts like reservoirs for delivering the drug to the targeted site. Micro pores use vander-wall forces for the controlled released of drug. Microporous surface also reduce the polymer load to 1/4th.
    • The Dual drug matrix is coated on the Abluminal side which ensures better Endothelialization and less systemic exposure of the drug.
    • Shellac Resin is the top coat of the stent for smooth surface which prevents dual drug matrix break ups during stent expansion.
    • Yukon Choice PC is one of the longest studied DES with 10 years of data establishing its safety and efficacy published in Circulation 

     

    Product Matrix/ Ordering Information

    Stent Diameter Ø  (mm)

    Stent length (mm) & Article number

    8

    12

    16

    18

    21

    24

    28

    32

    Ø2.00

    YCPC2008

    YCPC2012

    YCPC2016

    YCPC2018

    YCPC2021

    YCPC2024

    YCPC2088

    YCPC2032

    Ø2.25

    YCPC2208

    YCPC2212

    YCPC2216

    YCPC2218

    YCPC2221

    YCPC2224

    YCPC2228

    YCPC2232

    Ø2.50

    YCPC2508

    YCPC2512

    YCPC2516

    YCPC2518

    YCPC2521

    YCPC2524

    YCPC2528

    YCPC2532



    Stent Diameter Ø (mm)

    Stent length (mm) & Article number

    8

    12

    16

    18

    21

    24

    28

    32

    36

    40

    Ø2.75

    YCPC2708

    YCPC2712

    YCPC2716

    YCPC2718

    YCPC2721

    YCPC2724

    YCPC2728

    YCPC2732

    YCPC2736

    YCPC2740

    Ø3.00

    YCPC3008

    YCPC3012

    YCPC3016

    YCPC3018

    YCPC3021

    YCPC3024

    YCPC3028

    YCPC3032

    YCPC3036

    YCPC3040

    Ø 3.50

    YCPC3508

    YCPC3512

    YCPC3516

    YCPC3518

    YCPC3521

    YCPC3524

    YCPC3528

    YCPC3532

    YCPC3536

    YCPC3540

    Ø 4.00

    YCPC4008

    YCPC4012

    YCPC4016

    YCPC4018

    YCPC4020

    YCPC4024

    YCPC4028

    YCPC4032

    YCPC4036

    YCPC4040

    Compliance Chart

    Balloon Ø (mm)

    Inflation pressure (bar/105 Pa

     

    NP

     

     

     

     

     

     

    RBP

    6

    7

    8

    9

    10

    11

    12

    13

    14

    15

    16

    17

    18

    19

    20

    Ø 2.00

    1.90

    1.94

    1.97

    2.00

    2.03

    2.07

    2.10

    2.13

    2.17

    2.20

    2.23

    2.27

    2.32

    2.38

    2.41

    Ø 2.25

    2.15

    2.18

    2.47

    2.25

    2.28

    2.32

    2.35

    2.38

    2.42

    2.45

    2.49

    2.52

    2.55

    2.59

    2.62

    Ø 2.50

    2.40

    2.43

    2.21

    2.50

    2.54

    2.57

    2.64

    2.57

    2.67

    2.71

    2.74

    2.77

    2.81

    2.84

    2.88

    Ø 2.75

    2.65

    2.68

    2.72

    2.75

    2.78

    2.82

    2.88

    2.81

    2.92

    2.95

    2.98

    3.01

    3.28

    3.31

    3.34

    Ø 3.00

    2.89

    2.93

    2.97

    3.00

    3.04

    3.08

    3.15

    3.07

    3.19

    3.23

    3.26

    3.22

    3.34

    3.37

    3.41

    Ø 3.50

    3.37

    3.42

    3.46

    3.50

    3.54

    3.58

    3.67

    3.59

    3.71

    3.75

    3.79

    3.84

    3.88

    3.92

    3.96

    Ø 4.00

    3.85

    3.90

    3.96

    4.00

    4.05

    4.10

    4.21

    4.11

    4.26

    4.31

    4.36

    4.41

    4.46

    4.51

    4.56

     Technical Data

    Crossing Profile (Ø 2.5 mm)

    0.035’’/0.89 mm

    Strut Thickness (Ø 2.5 mm)

    0.0034’’/87µm

    Metallic Surface Area

    16-18%

    No Foreshortening

     

    Balloon Marker Material

    Platinum/ Iridium

    Entry Profile

    0.016’’/0.41 mm

    Proximal Shaft Diameter

    1.9 F

    Distal Shaft Diameter

    2.4 F

    Recommended Guide Wire

    0.014’’

    Guiding Catheter

    Min. 5 F

    Trade Information
    • 100000 Per Month
    • 1-7 Days
      Contact Us

      Ground Floor, Metro Tower, LSC, Mor Land, New Rajinder Nagar, New Delhi, Delhi, 110060, India
      Phone :+918037268771